SamsaraProvider course 4 of 4 · 12 min · 2 lessons

Samsara: ELD Malfunctions

How to read Samsara diagnostic and malfunction events, identify affected records, and track manual fallback and repair.

LESSON 2 / 2 · Manual duty records during an ELD malfunction

Manual duty records during an ELD malfunction

Keep duty records complete during a failure and close the issue with evidence.

What manual fallback records are

Manual fallback records are duty logs kept when an ELD malfunction prevents compliant recording. Reconstructing a log means rebuilding missing days from actual evidence.

For an ELD malfunction, the driver must rebuild today and the previous seven days on paper unless those logs are already available or can be retrieved. Help find the existing records and identify any missing days.

Ensure the driver continues required manual records until the ELD is back in compliance. The carrier’s ordinary repair deadline is eight days from discovery or notification, whichever comes first.

Separate missing records from a failed send

If accurate logs remain visible but transfer fails, help the driver present the compliant display or printout as directed and troubleshoot the send. Do not assume the duty data was lost.

If required records are missing or inaccurate, coordinate reconstruction and manual-recording duties. Use evidence of actual work rather than invented times.

Close the issue after checking recovery

Verify the driver, truck, current status, and new recorded events after repair. Retain the malfunction notice and manual logs. Check that the affected period is accounted for.

If repair needs more time, the carrier follows the FMCSA extension process. More paper logs do not restart the deadline.

Identify the failure before closing the issue

Samsara Power Malfunction details showing code P, detection time, and the reason for the event

What to check on this screen

  1. Capture the code, detection time, and stated cause for the issue record.
  2. Compare the affected period with the actual log. A cleared warning alone does not establish that missing records are complete.
© Samsara. Cropped to the event identity and cause. Use the official guide for the full troubleshooting instructions. Samsara: Diagnostic and Malfunction Events · Click image to enlarge.

A simple review routine

  1. Track required fallback days and continued manual records.
  2. Check the repair deadline and any extension process.
  3. Verify recording and retain the evidence before closing the issue.

Read the source

Previous lesson

Scope: ordinary US interstate property-carrying operations unless specified. Teaching examples are illustrative. Review the linked current sources and carrier policy. Content reviewed October 4, 2026.